Neonatology

BABYLIFE® BLR-2100 Neonatal warming and resuscitation table family

BABYLIFE® BLR-2100 Neonatal warming and resuscitation table family

The new BABYLIFE product, Neonatal Warming and Resuscitation Table, Model BLR-2100 released by MEDICOR Elektronika Zrt. is an up-to-date device to be used in obstetric wards and intensive care units. The temperature provided by model BLR 2100 through thermo-radiation is adjustable in a wide range while the radiator having optimum wavelength from physiologically optimum wavelength refrains the neonate from cooling down in the course of and following the necessary interventions. Features of Model BLR-2100: Microproccessor control, graphic LCD display, touch display-control board, alarm with LED display, APGAR display, ceramic heating elements. Operating modes: • Automatic pre-warm of lying surface temperature - 30 - 38 oC (Set: 33 oC) • Manual temperature control of lying surface • Automatic temperature control of lying surface - 30 - 38 oC • Automatic skin temperature control - 34 - 38 oC

Infusion pumps

Infusion pumps, Model ASSISTOR PCI

Widely used in intravenous therapy, allows accurate, continuous dosing of infusions that is easy to reproduce (e.g. I.C.U., internal medicine, general surgery, obstetrics-gynaecology, oncology, etc.) „Set-up” menu of the device allows the user to programme the required parameters. Programming is performed easily with the numeric keyboard. The device automatically recognises and displays the pre-programmed syringes of 10, 20, 30, 50/60, 100 ml.

Blood pressure gauge

SE 7000

Using the SE-7000: Place the cuff on the left upper arm. The cuff should not be too tight nor too loose.The measurement, inflating of cuff and the pressure reducing are automatic. Complete the measurement in a relaxed state, don't talk during the measurement arm and body has to be still. The main technical datas of the SE-7000 : Accuracy: ± 3 mmHg, pulse ± 5% Measuring range: between 20-280 mm Hg Heart Rate Monitor range: 40-200 pulsations / min "adaptive" optimal inflation features and automatic re-inflating and setting of the constant lowering speed of deflation depending on the heart rate Energy supply: 4 x 1.5V AA LR6 batteries or DC 6V power adapter type MEDAP Battery life: 3 months in daily use for about 3 minutes/day Memory: It stores 8 results of measurement Cuff size: 520 mm x 140 mm

Blood pressure gauge

SE - 4000

Using the SE-4000: Place the cuff on the left upper arm. The cuff should not be too tight nor too loose. Turn the unit on by pressing button Power. Check the level of pressure settings by pressing the button Pressure. This level has to be ca. 40 mmHg higher than your expected systolic blood pressure (higher level). Start the measurement by pressing button Start. Complete the measurement in a relaxed state, don't talk during the measurement arm and body has to be still. The main technical datas of the SE-4000 : Accuracy: ± 3 mmHg, pulse ± 5% Measuring range: between 20-300 mm Hg Heart Rate Monitor range: 40-200 pulsations / min Pumping: Automatic with micro pump upto the preset pressure level. If this is not enough automatic re-inflating happens at an increased pressure level Air retraction: Through magnetic valve at a constant rate Rapid retraction: Press a button positioned on ballpump Energy supply: 4 x 1.5V AA LR6 batteries or DC 6V power adapter type MEDAP Battery life: 3 months in daily use for about 3 minutes/day Memory: It stores 8 results of measurement Cuff size: 520 mm x 140 mm